Part Number Hot Search : 
ESD5V6 DS315107 ESD5V6 16245 2SC945 LTM4616V 020LF 2SB12
Product Description
Full Text Search
 

To Download NLP110-9605J Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 embedded power for business-critical continuity nlp110 series single and triple output special features ? provides low voltage outputs ? compliance to en61000-3-2 (power factor = 0.98) ? 90 vac to 264 vac universal input range ? ul, csa and vde safety approvals and ce-marked to lvd ? overvoltage and short circuit protection ? vde0871-b, en55022-b, en55011-b conducted noise ? vde0871-a, en55022-a, en55011-a radiated noise ? meets all applicable and relevant immunity standards en61000-4-2,4,5 and 6 ? rohs compliant ? 2 year warranty safety vde0805/en60950/iec950 file no. 10401-3336-1096 ul1950 file no. e136005 csa c22.2 no. 950 file no. lr41062 ccc mark ? ? ? ? rev. 02.10.09_152 nlp110 series 1 of 4 electrical specifcations total power: 80-110 watts input voltage: 90 -264 vac # of outputs: single, triple input input range: universal input (see note 6) 90-264 vac frequency: 47-63 hz input surge current: (cold start) 120 vac 230 vac 18 a max. 35 a max. safety ground leakage current: 120 vac, 60 hz 230 vac, 50 hz 0.45 ma 0.75 ma input current: 120 vac @ 80 w 120 vac @ 110 w 230 vac @ 80 w 230 vac @ 110 w 0.9 a rms 1.3 a rms 0.48 a rms 0.7 a rms input fuse: ul/iec127 f3.15a h, 250 vac output total regulation: (line and load) main output auxiliary outputs 2.0% 5.0% rise time: at turn-on 1.0 s, max. transient response: main output 75% to 100% step at 0.1 a s 5.0% or 250 mv max. dev., 1 ms max. recovery to 1% temperature coeffcient: 0.02%/c overvoltage protection: main outputs 125%, 10% short circuit protection: cyclic operation continuous minimum output current: single and multiple see table all specifcations are typical at nominal input, full load at 25 c unless otherwise stated.
rev. 02.10.09_152 nlp110 series 2 of 4 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 environmental specifcations emc characteristics conducted emissions: en55022, fcc part 15 level b radiated emissions: en55022, fcc part 15 level a harmonic current emission correction: en61000-3-2 compliant esd air: en61000-4-2 level 3 esd contact: en61000-4-2 level 3 surge: en61000-4-5 level 3 fast transients: en61000-4-4 level 3 radiated immunity: en61000-4-3 level 3 conducted immunity: en61000-4-6 level 3 general specifcations hold-up time: 120 vac, 60 hz 16.7 ms @ 110 w effciency: 120 vac. 80 w (-9905j) 75% min. isolation voltage: input/output input/chassis 3000 vac 1500 vac approvals and standards pending: en60950, vde0805, iec950, ul1950, csa c22.2 no. 950 weight: 283 g (10 oz) mtbf demonstrated: mil-hdbk-217f 220,000 hours min. thermal performance: operating, ambient (see derating curve) 0 c to +50 c non-operating -40 c to +85 c 50 c to 70 c ambient convection cooled derate to 50% load 0 c to +50 c, ambient convection cooled 80 w 0 c to +50 c, ambient, 150 lfm forced air 110 w peak (0 c to +50 c, 60 s) (see note 3) relative humidity: non-condensing 5% to 95% rh altitude: operating 10,000 feet max. non-operating 30,000 feet max. vibration (see note 5): 5-500 hz 2.4 g rms peak shock per mil-std-810e 516.4 part iv dera ting cur ve output power (w atts) 0c 10c 20c 30c 40c 50c 60c 70c 40w 80w 11 0w 150 lfm forced air cooling 55w na tura l convection cooling
rev. 02.10.09_152 nlp110 series  of 4 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 notes 1 free air convection. multiple output units: maximum continuous output power not to exceed 80 w. for -9693j; i 3.3 v = 13 a max.; i 5.0 v = 13 a max.; i 3.3 v + i 5.0 v 2 16 a. for -9694j; i 3.3 v = 13 a max.; i 2.5 v = 13 a max.; i 3.3 v + i 2.5 v 2 16 a for -9695j; i 3.3 v = 13 a max.; i 12 v = 6.5 a max.; i 3.3 v + i 12 v 2 16 a. for -9608j; i 5.0 v = 13 a max.; i 12 v = 6.5 a max.; i 5.0 v + i 12 v 2 16 a. single output units: maximum continuous output power not to exceed; 75 w on -9905j; 76.8 w on -9912j,-9924j, and -9917j. 2 150 lfm forced air cooling from l4 side. multiple output units: maximum continuous output power not to exceed 105 w. for -9693j; i 3.3 v = 16 a max.; i 5.0 v = 16 a max.; i 3.3 v + i 5.0 v 2 20 a. for -9694j; i 3.3 v = 16 a max.; i 2.5 v = 16 a max.; i 3.3 v + i 2.5 v 2 20 a for -9695j; i 3.3 v = 16 a max.; i 12 v = 8.5 a max.; i 3.3 v + i 12 v 2 20 a. for -9608j; i 5.0 v = 16 a max.; i 12 v = 8.5 a max.; i 5.0 v + i 12 v 2 20 a. single output units: maximum continuous output power not to exceed 110 w for all models. 3 300 lfm forced air cooling from l4 side. multiple output units: maximum continuous output power not to exceed 110 w. for -9693j; i 3.3 v = 20 a max.; i 5.0 v = 18 a max.; i 3.3 v + i 5.0 v 2 22 a. for -9694j; i 3.3 v = 20 a max.; i 2.5 v = 20 a max.; i 3.3 v + i 2.5 v 2 22 a for -9695j; i 3.3 v = 20 a max.; i 12 v = 8.5 a max.; i 3.3 v + i 12 v 2 22 a. for -9608j; i 5.0 v = 20 a max.; i 12 v = 8.5 a max.; i 5.0 v + i 12 v 2 22 a. single output units: maximum continuous output power not to exceed 110 w for all models. 4 peak output current lasting less than 30 seconds with duty cycle less than 5%. during peak loading, output voltage may exceed total regulation limits. 5 figure is peak-to-peak for convection power rating. output noise measurements are made across a 20 mhz bandwidth using a 6 twisted pair, terminated with a 10 f electrolytic capacitor and a 0.1 f ceramic capacitor. 6 minimum load required for correct start-up and operation on single outputs and on main output of multiple versions. failure to observe minimum load on main output will not allow the supply to start-up correctly. some electronic test loads have a large delay time before they start drawing current even though the voltage from the supply is present. during this time delay, there is no load on the output and as a result, the supply cannot start- up properly and maintain its correct output voltage. in these instances, a dummy resistive load across the output may be necessary to load the output of the supply until the test load can function correctly and draw the intended minimum load. minimum load required on auxiliary outputs to maintain regulation. 7 for models nlp110-9608j and nlp110-9695j, the 12 v output is foating. for -12 v output, pin 11 on j2 has to be connected to return making pin 12 the -12 v output 8 three orthogonal axes, random vibration 10 minutes for each axes, 2.4 g rms 5 hz to 500 hz. 9 for optimum reliability, no part of the heatsink should exceed 110 ?c, and no semiconductor case temperature should exceed 120 ?c. 10 caution: allow a minimum of 1 second after disconnecting line power when making thermal measurements. 11 this product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 12 the emi specifcations reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. no external fltering required during conducted emissions testing but some applications may require additional fltering to achieve system compliance. a line choke, (ac input cords looped twice through an emi suppression toroid) was used during radiated emissions testing. considerable radiated testing in 1u six-sided boxes has shown that units can meet level b in typical systems. application support is available from the factory to assist with emi compliance. 13 all models require a minimum mounting stand-off of 6.35 mm (0.25 inches) in the end use product. 14 the j suffx indicates that these parts are pb-free (rohs 6/6) compliant. 15 notice: some models do not support all options. please contact your local emerson network power representative or use the on-line model number search tool at http://www.powerconversion.com/products. ordering information output voltage min (6) max (1) 150 lfm (2) 300 lfm (3) peak (4) ripple (5) total regulation model numbers (7, 14, 15) +5 v 0.5 a 15 a 22 a 22 a 22 a 50 mv 2.0% NLP110-9605J +12 v 0.3 a 6.4 a 9.2 a 9.2 a 11.5 a 120 mv 2.0% nlp110-9612j +48 v 0 a 1.6 a 2.3 a 2.3 a 2.5 a 240 mv 2.0% nlp110-9617j +24 v 0.2 a 3.2 a 4.6 a 4.6 a 6.0 a 240 mv 2.0% nlp110-9624j +5 v (a) 0.5 a 13 a 16 a 18 a 18 a 50 mv 2.0% nlp110-9693j +3.3 v (b) 0.2 a 13 a 16 a 20 a 20 a 50 mv 2.0% +12 v 0 a 0.65 a 1 a 1 a 1 a 120 mv 5.0% +3.3 v (a) 0.5 a 13 a 16 a 20 a 22 a 50 mv 2.0% nlp110-9694j +2.5 v (b) 0.1 a 13 a 16 a 20 a 22 a 50 mv 2.0% +12 v 0 a 0.65 a 1 a 1 a 1 a 120 mv 5.0% +12 v (a) 0.2 a 6.5 a 8.5 a 8.5 a 10 a 120 mv 2.0% nlp110-9695j +3.3 v (b) 0.5 a 13 a 16 a 20 a 22 a 50 mv 2.0% -12 v 0 a 0.65 a 1 a 1 a 1 a 120 mv 5.0% +12 v (a) 0.2 a 6.5 a 8.5 a 8.5 a 10 a 120 mv 2.0% nlp110-9608j +5 v (b) 0.2 a 13 a 16 a 18 a 22 a 50 mv 2.0% -12 v 0 a 0.65 a 1 a 1 a 1 a 120 mv 5.0%
313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 embedded power for business-critical continuity rev. 02.10.09_152 nlp110 series 4 of 4 0.23 (5.842) 6.50 (165.10) 1 t1 (ref.) j4 j1 6.050 (153.670) 2.550 (64.770) all dimensions in inches (mm) j2 j3 1 1 2 12 3.00 (76.20) f1 j5 2 1 0.23 (5.842) ! 3 maximum component height is 1.26 (32.00) input and output connectors mating connectors ac (j1) connector type molex 26-60-4030 or equivalent. valent. ac (j1) mating connector type molex 09-50-3031 or equivalent with molex 08-50-0105 or equivalent crimp terminals. terminals. dc (j2) connector type 12 position molex spox type 26-48 1125 or equivalent. equivalent. dc (j2) mating connector type molex spox type 26-03-3121 and contact 08-52-0113. 08-52-0113. sense (j3) connector type molex 22-23-2021 o r equivalent. equivalent. sense (j3) mating connector type molex 22-01-3027 and contac t 08-50-0113. t 08-50-0113. earth (j4) connector type male 0.250 qui ck disconnect. ck disconnect. earth (j4) mating connector ty pe pe molex 90028. sense (j5) connector type leo co 2421p02h000. co 2421p02h000. sense (j5) mating connector type leoco 2420s020000 and co ntact 2453tpb00v1. ntact 2453tpb00v1. 2 3 4 1 recommended direction for forced air relative to power supply orientation shown below. 1 optimum. 2 very good. 3 good. 4 not recommended. input pin connections j1 pin 1 ac neutral pin 2 no connection pin 3 ac line j3 pin 1 v (a) sense + pin 2 v (a) sense - j4 pin 1 safety earth j5 pin 1 v (b) sense + pin 2 v (b) sense - output pin connections j2 single triple pin 1 no connection v (b) pin 2 no connection v (b) pin 3 no connection v (b) pin 4 return return pin 5 return return pin 6 return return pin 7 return return pin 8 v (a) v (a) pin 9 v (a) v (a) pin 10 v (a) v (a) pin 11 no connection v (c) pin 12 no connection v (c) return (7 americas 5810 van allen way carlsbad, ca 92008 usa telephone: +1 760 930 4600 facsimile: +1 760 930 0698 europe (uk) waterfront business park merry hill, dudley west midlands, dy5 1lx united kingdom telephone: +44 (0) 1384 842 211 facsimile: +44 (0) 1384 843 355 asia (hk) 14/f, lu plaza 2 wing yip street kwun tong, kowloon hong kong telephone: +852 2176 3333 facsimile: +852 2176 3888 for global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com while every precaution has been taken to ensure accuracy and completeness in this literature, emerson network power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. emerson network power and the emerson network power logo are trademarks and service marks of emerson electric co. ?2008 emerson electric co. emersonnetworkpower.com embedded computing embedded power monitoring outside plant power switching & controls precision cooling racks & integrated cabinets services surge protection emerson network power. the global leader in enabling business-critical continuity. ac power connectivity dc power


▲Up To Search▲   

 
Price & Availability of NLP110-9605J

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X